Roof Sheathing Thickness 16 Oc

Pin By Jackie Urra Ra On Common Problems Solutions Roof Insulation Roof Detail Roof Shingles

Pin By Jackie Urra Ra On Common Problems Solutions Roof Insulation Roof Detail Roof Shingles

Related Image Roof Insulation Roof Detail Roof Shingles

Related Image Roof Insulation Roof Detail Roof Shingles

Name Garages Layout2 Jpg Views 6123 Size 32 4 Kb Garage Plans How To Plan Shed Plans

Name Garages Layout2 Jpg Views 6123 Size 32 4 Kb Garage Plans How To Plan Shed Plans

Km 7fw4p Ofgpm

Km 7fw4p Ofgpm

Residential Drawings Roof Edge Gutters House Wiring

Residential Drawings Roof Edge Gutters House Wiring

Inspecting Roof Panel Sheathing Internachi

Inspecting Roof Panel Sheathing Internachi

Inspecting Roof Panel Sheathing Internachi

For rafters spaced 20 or more inches apart 1 2 or 5 8 inch plywood is recommended.

Roof sheathing thickness 16 oc.

Roof sheathing comes in grid marked 4 by 8 foot sheets and should be installed perpendicular to the frame. What about the roof sheathing at 24 in. The most common rafter spacing is 24 inches and 5 8 inch plywood is recommended for that. For the curious 7 16 osb has a span rating of 24 16 and with supports every 24 inches is good for a roof live load of 40 psf pounds per square foot with a 10 psf dead load.

Sheathing should be a minimum of 19 32 inch thick. 1 inch 25 4 mm. Panels are rated 32 16. I m contemplating upgrading to 1 2 or even 5 8 osb though to reduce roof sag hopefully to nil.

Roof sheathing shall be structural wood panels plywood osb with a minimum five eighths inch thickness grade stamped for use and span. Floor or roof sheathing conforming with this table shall be deemed to meet the design criteria of section 2304 7. For subfloors zip s 1 2 in. For rafters or 16 in.

We re in dallas so we don t engineer for tremendous live loads for an asphalt shingle and we feel comfortable with 16 oc rafter spacing and 7 16 osb decking. That means it can be used at 24 in. Huber s zip system sheathing which we are using on the fhb house has a span rating of 24 16 for 7 16 in. The thickness required by josh s circumstances are good for roof snow loads of up to 70 psf again spanning 24.

Never attach roof sheathing with staples. 8d ring shank nails should be used instead. Secure roof sheathing panels to the roof framing with 8d common nails spaced six inches on center at the edges and twelve inches on center at intermediate supports.

Https Www Huberwood Com Uploads Documents Technical Documents Shear Capacity Comparison Of Plywood And Zip System Sheathing Tech Tip Wall Zip System Pdf

Https Www Huberwood Com Uploads Documents Technical Documents Shear Capacity Comparison Of Plywood And Zip System Sheathing Tech Tip Wall Zip System Pdf

Gallery Of 16 Brick Cladding Constructive Details 12 Brick Cladding Cladding Brick

Gallery Of 16 Brick Cladding Constructive Details 12 Brick Cladding Cladding Brick